Imaginile produselor au caracter informativ si pot prezenta diferente minore, in functie de lot si de furnizor. Este posibil ca specificatiile si pretul produselor sa fie modificate fara preaviz. Facem tot posibilul sa adaugam in pagina produselor specificatii cat mai exacte si corecte dar este posibil ca acestea sa nu fie in totalitate corecte. in cazul in care identificati un astfel de caz, va rugam sa ne semnalati acest lucru.
Produsul este destinat specialistilor si nu include instructiuni de asamblare/utilizare. Produsul beneficiaza de garantia legala de conformitate (produsul este conform specificatiilor din site) egala cu durata de functionare medie a produsului de 14 zile de la data primirii produsului si de garantia Dead on Arrival (nefunctional la primire).
6 Low Current Dc Control Ac Solid State Relay Module Low Level Trigger 5V/12V/24V (Optional)
Specificatii:
1. Solid state relay 240V 2A, output with resistance fuse 240V 2A.
2. Size: 80*56*25 (length * width * height) Net weight: 60g
3. Input power: 5V 12V 24V 3-24V
4. Input control signal voltage:
0-2.5V state low level relay ON)
(3.3-5V state high level relay OFF)
5. It is more convenient to have 2.54CM pin and blue KF301 terminal to connect the control line.
Module interface:
Input section:
DC+: Connect the positive pole of the power supply (powered by the relay voltage)
DC-: connected to the negative pole of the power supply
CH1: 1 relay module signal trigger terminal (low level trigger is valid)
CH2: 2-way relay module signal trigger terminal (low level trigger is valid)
CH3: 3-way relay module signal trigger terminal (low level trigger is valid)
CH4: 4-way relay module signal trigger terminal (low level trigger is valid)
CH5: 5-way relay module signal trigger terminal (low level trigger is valid)
CH6: 6-way relay module signal trigger terminal (low-level trigger is valid)
High and low meaning:
High-level triggering means that there is a forward voltage between the signal trigger terminal (IN) and the negative pole of the power supply. Usually, a triggering method is used to connect the positive pole of the power supply to the trigger terminal. When the trigger terminal has a positive voltage or triggers. At the voltage, the relay pulls in.
Low-level triggering means that the voltage between the signal trigger terminal and the negative pole of the power supply is OV, or the voltage at the trigger terminal is lower than the voltage of the positive pole of the power supply. When the voltage is low enough to trigger, the relay is pulled in, usually A triggering method in which the negative pole of the power supply is connected to the trigger terminal, so that the relay is attracted.
Electrical parameters:
Voltage version Quiescent current Operating current Trigger voltage Trigger current
1 way 5V 0mA 13.8mA 0-2V 2mA
2 way 5V 0mA 26.8mA 0-2V 2mA
3-way 5V 0mA 37mA 0-2V 2mA
4 way 5V 0mA 48mA 0-2V 2mA
5 way 5V 0mA 59mA 0-2V 2mA
6 way 5V 0mA 70mA 0-2V 2mA
feedback Report comment