Imaginile produselor au caracter informativ si pot prezenta diferente minore, in functie de lot si de furnizor. Este posibil ca specificatiile si pretul produselor sa fie modificate fara preaviz. Facem tot posibilul sa adaugam in pagina produselor specificatii cat mai exacte si corecte dar este posibil ca acestea sa nu fie in totalitate corecte. in cazul in care identificati un astfel de caz, va rugam sa ne semnalati acest lucru.
Produsul este destinat specialistilor si nu include instructiuni de asamblare/utilizare. Produsul beneficiaza de garantia legala de conformitate (produsul este conform specificatiilor din site) egala cu durata de functionare medie a produsului de 14 zile de la data primirii produsului si de garantia Dead on Arrival (nefunctional la primire).
1 Way 12V Relay Module with Shell Adjustable Trigger Delay Cycle Timing Pull on Switch Multifunction timer with box
Specificatii:
1. The signal triggers the relay to pull in. When the time is up, the relay is disconnected during the delay period.
A: Invalid trigger again B: Re-trigger re-clocking C: Trigger relay reset again to stop timing
2. The signal triggers the start timing time T1, and the time is up to the relay pull-in time T2. The time to turn off (reset) T1 and T2 is adjustable.
3. Recycling: Turn on T1, disconnect T2, infinite loop. Both T1 and T2 are adjustable
4. There is signal, the relay is closed, the suction is kept, the signal disappears, the timing starts, the time is up, the relay is disconnected, during the delay, the signal is given again, the delay is cancelled, the signal disappears, and the time is re-timed.
Video demo address: http://v.youku.com/v_show/id_XNzkyNzgxMTk2.html
The relay is closed, the normally open end and the common end are connected, and the normally closed end and the common end are disconnected; the working mode is selected: after the power is turned on, long press K1 for 2 seconds to enter the selected function mode.
P1—1~P1—4 can be selected, P1-1 working mode: the signal triggers the relay to pull in. When the time is up, the relay is disconnected. The user can set the time T of the relay to pick up, press the K2 hundred digit digital tube to start flashing. At this time, press K3, the hundred digits change; press K2 ten digits to start flashing, press K3 at this time, the ten digits change; press K2 digits to start flashing, press K3, one digit Digital change; press K2 again; the digital tube no longer flashes, press K3 at this time, the decimal point shifts, the decimal point in the single digit means 0 to 999 minutes, the ten digits represent 0 to 99.9 seconds, and the decimal point does not represent 0 to 999 seconds; After you have selected it, the time is set. Short press K1 to enter the fine adjustment setting of the function. The trigger is invalid during the default delay. Press K1, the trigger is valid during the delay (re-timer), press K1, reset during the delay (time off, relay reset), Press again to repeat the default first time setting.
P1-2 working mode: signal trigger start timing X time to relay pull-in Y disconnect. The user can set the time X, Y of the relay pull-in; the time setting is similar to P1-1. The blue light is on to indicate the time when the relay is closed, and the blue light is off to set the time when the relay is disconnected. Short press K1 to enter the fine adjustment setting of the function. The trigger is invalid during the default delay. Press K1, the trigger is valid during the delay period (re-timer), and then press the default first setting.
P1-3 working mode: turn on X seconds, disconnect Y seconds, infinite loop. The user can set the time X, Y of the relay pull-in; the time setting is similar to P1-2. Short press K1, you can enter the fine adjustment settings of the function, first turn on X, turn off Y seconds, press K1, first disconnect X, turn on Y seconds, then press again to repeat the default first setting.
P1-4 working mode: the signal triggers the relay to pull in but does not start timing, the trigger signal disappears and starts timing T. When the time is up, the relay is turned off; during the delay, the signal is given again, the delay is cancelled, the suction is kept, and the signal disappears. Restart the timing; (equivalent to the start of the button release, often used for power-off delay). The user can set the time T for the relay to pull in; the time setting is similar to P1-1.