# Delay relay module with Mosfet, adjustable time, display, 5-36V

> Delay relay module with MOSFET, adjustable time, display, powered from 5-36V DC. Trigger signal 3-24V, output as closed-open contact, dual MOS output with low internal resistance, handles loads up to 15A/400W. Time resolution 0-99.9s, 0-999s or 0-999min, 4 operating programs (P1-P4), operating temperature -40...85C, dimensions 60x34x12mm.

- Page: https://sigmanortec.ro/en/delay-relay-module-with-mosfet-adjustable-time-display-5-36v
- Price: 11.00 RON
- Availability: In stock; 1-2 zile
- Reference: 9007 · EAN: 5942151759671
- Category: Electronic components > Timer Modules
- Specifications: Supply Voltage: 5 V; Maximum Input Voltage: 36 V; Output Type Voltage: Closed-Open Contact; Input Voltage Type: “DC” in Romanian can mean **“de ce”**, which translates to **“why”** in English.
- Package (shipping data): 0.017 kg
- Updated: 2026-09-14
- Shop: [Sigmanortec.ro](https://sigmanortec.ro/en/llms.txt)
- Prices: RON, VAT included; prices and stock as of 2026-10-22 02:22 (Europe/Bucharest)

## Description

Timer module and MOSFET control for DC automation, allows delayed start, delayed stop or ON OFF cycling, with easy setting on the display. It operates at 5-36V and accepts 3-24V trigger signal. The silent output with low internal resistance switches large loads up to 15A, offering a longer life than classic relays.
Programmable relay module with timer for delayed control with digital display. It can be powered with a voltage between 6 and 30VDC.
The time resolution can be set.
Infinite number of switches.
Switching does not produce the sound of a classic relay.
Longer lifespan compared to a classic relay.
Active dual MOS parallel output, low internal resistance and ability to operate with high loads (15A and 400W at ambient temperature).
Specifications:
Supply voltage: 5 - 36V via connectors
Trigger signal: High Level, 3 - 24V
Control output: DC 5V--36V, constant current 15A at room temperature, power 400W
Dimensions mm: 60 x 34 x 12mm
Operating temperature: -40 - 85C
Time resolution: 0-99.9 seconds, 0-999 seconds, 0-999 minutes
Programs:
- Program 1 (P-1): Upon receiving the signal the module will activate the relay and start the timer. The relay will deactivate when the time expires. Requires a short signal. Keeping the signal active will not activate the module again.
- Program 2 (P-2): Upon receiving the signal, the module will remain off for a set time, then it will activate for a set time and finally turn off.
- Program 3 (P-3): Does not require a signal, the module can activate the relay (ON time) and deactivate (OFF time) in a "loop".
- Program 4 (P-4): Initially remains active as long as the signal is active. When the signal stops, the module starts counting and the relay turns off.
Mode of Operation:
Program | General Description | Submode/Function | Detailed Behavior
P-1 | The relay is activated by a short signal and deactivated after a set time (OP). | P1.1 | Ignore any new signal during OP.
P1.2 | A new signal restarts the OP timer.
P1.3 | A reset signal deactivates the relay and stops the timer.
P-2 | After a trigger signal, it waits a time (CL), then activates the relay for the OP duration. | — | The relay activates after the CL delay, then turns off after the OP.
P-3 | It operates cyclically in the ON/OFF loop, with or without a signal. | P3.1 | The ON (OP)/OFF (CL) cycle begins upon receipt of the trigger signal.
P3.2 | The ON (OP)/OFF (CL) cycle starts automatically upon power-up, without a signal.
P-4 | The relay remains active as long as there is a signal. When the signal disappears, the OP count starts and then stops. | — | The OP timer starts after signal loss. During signal, it resets.
Time Settings:
After setting the values in the mode selection screen, short press the STOP button to select the time interval. Example: If you want to set the OP to 3.2 seconds, move the decimal point and the display will show 03.2.
Description Parameters:
The parameters are independent, but each mode has common parameters.
Parameter Settings:
First determine the relay's operating mode.
To select the operating mode, in the main interface (when starting up), "press and hold the SET button for 2 seconds", then use the UP and DOWN buttons to select the desired mode.
After choosing the mode, press the SET button to set the desired parameters.
After all settings are completed, press and hold the SET button for 2 seconds.
STOP Button Functions:
- Relay Activation Mode:
ON: The relay is allowed to activate during OP.
OFF: The relay is always off.
- Sleep Mode:
CP: Without operation for 5 minutes, the display turns off, but the program operates normally.
Od: The display always stays on.
To switch between CP and Od modes, press and hold the STOP button for two seconds.